Tempco Temperature Control Options

/Tempco/Data-Assets/09-Flexible-Images/WebS611.jpg

Snap Action Thermostat – Automatic Reset

Quick cutout on rise to temperature. The contacts will open on rise when the temperature increases to the snap point of the calibrated bimetal disc.

Setpoint (opens): available from 50 to 450°F in 10°F increments (most thermostats close 20 to 30°F below setpoint)
Electrical Ratings: 125 Vac, 15 Amp, 1875W, 250 Vac, 10 Amp, 2500W
Minimum Heater Width: 1.312″

/Tempco/Data-Assets/09-Flexible-Images/WebS610.jpg

Adjustable Thermostat

Adjustable thermostats allow the user to dial-in a specific temperature and attain a desired result. The thermostat is enclosed in a molded silicone rubber housing and permanently attached to the heater. The adjustment shaft extends through a pre-formed hole. A high temperature knob is included.
Amps: 12.5A @ 125V, 6.5 A @ 250V
Watts: 1500W @ 120V, 1560W @ 240V
Adjustment Ranges Available:

  • 50 to 425°F (10 to 218°C)
  • 90 to 140°F (32 to 60°C)
  • 100 to 190°F (38 to 88°C)
  • 70 to 190°F (21 to 88°C)
  • 50 to 160°F (10 to 71°C)
  • 70 to 140°F (21 to 60°C)

Minimum Heater Width: 1.75″ (44.5 mm)

/Tempco/Data-Assets/13-Temp-Control-Images/WebJ504.jpg

Snap Action High Limit Thermostat

A High Limit with a manual reset push button can also be designed in.
Specify when requesting a quote.
NOTE: See page 13-83 for stock temperature ratings

/Tempco/Data-Assets/09-Flexible-Images/WebS612.jpg

Creep Action Thermostat

Sustained response, and a slow cutout at the trip point. The creep action thermostat has a slow make/slow break action around setpoint.
Setpoint (opens): available in a limited selection from 50 to 300°F in 10°F increments. Consult Tempco.
Electrical Ratings: 120 Vac, 12 Amp, 1440W, 240 Vac, 6 Amp, 1440W

/Tempco/Data-Assets/13-Temp-Control-Images/WebJ505.jpg

Thermal Fusing

Thermal fuses / cutoffs are used as high limit protection devices to guard the object being heated from dangerous temperatures in the event of a primary control device failure. The thermal fuse can be mounted using various methods depending on other options. If the heater does not have a thermostat, the thermal fuse would be mounted under the lead exit patch. If used in conjunction with a thermostat, it could be mounted under the thermostat cover.