Type T2: Screw Terminals, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/25A
Type T2: Screw Terminals, Two-Piece Band
Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/25A each half
Type T3: Screw Terminals, One-Piece Band
Standard Termination Location: opposite the gap; across the center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts/Amps: 480VAC/25A
Type T3: Screw Terminals, Two-Piece Band
Standard Termination Location: center of each half; across the center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts/Amps: 480VAC/25A each half
Type L1: Straight Lead Wires, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A
Type L1: Straight Lead Wires, Two-Piece Band
Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half
Type W1: Abrasion Resistant Straight Wire Braid Leads, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A
Type W1: Abrasion Resistant Straight Wire Braid Leads, Two-Piece Band
Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half
Type R1: Abrasion Resistant Straight Armor Cable, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A
Type R1: Two-Piece Band Abrasion Resistant Straight Armor Cable
Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half
Type R2: Abrasion Resistant Right-Angle Armor Cable, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A
Type R2: Abrasion Resistant Right-Angle Armor Cable, Two-Piece Band
Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half
Type S1: Lead Wire Spring Strain Relief, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A
Type S1: Lead Wire Spring Strain Relief, Two-Piece Band
Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half
Type C2: Standard Terminal Box, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 1-1/2″ (38.1 mm)
Maximum Volts/Amps: 480VAC/25A
Type C2: Standard Terminal Box, Two-Piece Band
Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 1-1/2″ (38.1 mm)
Maximum Volts/Amps: 480VAC/25A each half
Type C5: Low-Profile Terminal Box, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 1-1/2″ (38.1 mm)
Maximum Volts/Amps: 480VAC/25A
Type C5: Low-Profile Terminal Box, Two-Piece Band
Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 1-1/2″ (38.1 mm)
Maximum Volts/Amps: 480VAC/25A each half
Type P1: High-Temperature Quick Disconnect Plugs, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 2″ (50.8 mm) depending on termination orientation
Type P1: High-Temperature Quick Disconnect Plugs, Two-Piece Band
Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 2″ (50.8 mm) depending on termination orientation
Type P2: High-Temperature Quick Disconnect Plugs, Low-Profile, One-Piece Band
Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 2″ (50.8 mm)
Minimum Width: 2″ (50.8 mm)
Type P2: High-Temperature Quick Disconnect Plugs, Low-Profile, Two-Piece Band
Standard Termination Location: center of each half; center of width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 2″ (50.8 mm)
Type P3: DIN 49458 A/B Quick Disconnect Plugs, Vertical, One-Piece Band
Standard Termination Location: opposite the gap; center of width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 2″ (50.8 mm)
Type P3: DIN 49458 A/B Quick Disconnect Plugs, Vertical, Two-Piece Band
Standard Termination Location: center of each half; center of width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 2″ (50.8 mm)
Type P4: DIN 49458 A/B Quick Disconnect Plugs, Horizontal, One-Piece Band
Standard Termination Location: opposite the gap; center of width
Minimum Inside Diameter: 2-1/2″ (63.5 mm)
Minimum Width: 2-1/2″ (63.5 mm)
Type P4: DIN 49458 A/B Quick Disconnect Plugs, Horizontal, Two-Piece Band
Standard Termination Location: center of each half; center of width
Minimum Inside Diameter: 4″ (101.6 mm)
Minimum Width: 2-1/2″ (63.5 mm)
Manage Cookie Consent
We use cookies to optimize our website and our service.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.