Amerimation SR2/SR3 Series – Three Phase
Eagle Sensors is an authorized Amerimation distributor. Please contact us for application & sales support.
Key Features
- Two mounting hole types and sizes
- Alarm output (overheating): Alarm output indicator (red LED), disconnect standard output, alarm output
- Dielectric strength: 4000 VAC (also 2,500VAC model)
- High heat dissipation efficiency with ceramic PCB andintegrated heatsink
- Zero cross turn-on, random turn-on models available
- Input indicator (green LED)
- Varous mounting methods (DIN rail, panel) – SRH2/SRH3 series
①Type
No mark |
Detachable heatsink type |
H |
Integrated heat sink type |
|
②Control phase
2 |
3-phase (2-pole) |
3 |
3-phase (3-pole) |
|
③Rated input voltage
1 |
4-30VDC |
2 |
24VAC |
4 |
90-240VAC |
|
④Rated load voltage
⑤ Rated load current (resistive load)
15 |
15A |
25 |
25A |
40 |
40A |
50 |
50A |
75 |
75A |
|
⑥ Function
No Mark |
Zero cross turn-on |
R |
Random turn-on |
|
Specifications
1. Input
Rated input voltage range |
4-30VDC |
24VACrms (50/60Hz) |
90-240VACrms (50/60Hz) |
Input voltage range |
4-32VDC |
19-26.4VACrms (50/60Hz) |
85-264VACrms (50/60Hz) |
Max. input current |
25mA |
15mA |
25mA |
Pick-up voltage |
Min. 4VDC |
Min. 19VACrms |
Min. 85VACrms |
Drop-out voltage |
Max. 1VDC |
Max. 4VACrms |
Max. 10VACrms |
Turn-on time |
Zero cross turn-on |
Max. 0.5 cycle of load source + 1ms |
Max. 1.5 cycle of load source + 1ms |
Random turn-on |
Max. 1ms |
– |
– |
Turn-off time |
Max. 0.5 cycle of load source + 1ms |
Max. 1.5 cycle of load source + 1ms |
|
2. Output
Rated load voltage range |
24-240VAC load voltage |
48-480VAC load voltage |
Load voltage range(50/60Hz) |
24-264VACrms(50/60Hz) |
48-528VACrms(50/60Hz) |
Rated load current |
Resistive load (AC-51) |
15Arms |
30Arms |
50Arms |
75Arms |
15Arms |
30Arms |
40Arms |
50Arms |
75Arms |
Min. load current |
0.15Arms |
0.2Arms |
0.5Arms |
0.5Arms |
Max. 1 cycle surge current (60Hz) |
250A |
400A |
1000A |
300A |
500A |
1000A |
Max. non-repetitive surge current (I2t, t=8.3ms) |
340A2S |
1000A2S |
4000A2S |
350A2S |
1000A2S |
4000A2S |
Peak voltage (non-repetitive) |
600V |
1200V (Zero cross turn-on), 1000V (Random turn-on) |
Leakage current (Ta=25℃) |
Max. 10mArms (240VACᜠ/60Hz) |
Max. 10mArms (480VACᜠ/60Hz) |
Output on voltage drop [Vpk] (Max. load current) |
Max. 1.6V |
Static off-state dv/dt |
500V/㎲ |
|
3. Alarm output (Temperature overheat)
Rated input voltage range |
4-30VDC |
24VACrmsᜠ (50/60Hz) |
90-240VACrms (50/60Hz) |
Load input voltage |
Max. 30VDC |
Max. 30VDC |
Max. 30VDC |
Load input current |
Max. 100mA |
Max. 50mA |
Max. 50mA |
Turn-off time |
Max. 20ms |
Max. 40ms |
Max. 40ms |
|
4. General Specifications
Dielectric strength (Vrms) |
24-240VAC rated load current 15A/30A : 2500VAC 50/60Hz 1 min (Input-Output, Input/Output-Case) |
24-240VAC rated load current 50A/75A 48-480VAC rated load current 15A/30A/40A/50A/75A : 4000VAC 50/60Hz 1 min (Input-Output, Input/Output-Case) |
Insulation resistance |
Over 100MΩ (at 500VDC megger) (Input-Output, Input/Output-Case) |
Indicator |
Input indicator: Green LED / Alarm output indicator: Red LED |
Vibration |
Mechanical |
0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour |
Malfunction |
0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min |
Shock |
Mechanical |
300m/s² (approx. 30G) in each X, Y, Z direction for 3 times |
Malfunction |
100m/s² (approx. 30G) in each X, Y, Z direction for 3 times |
Environment |
Ambient temperature |
-30 to 80℃ (in case of the rated input voltage 90-240VAC: -30 to 70℃), Storage: -30 to 100℃ |
Ambient humidity |
45 to 85%RH, Storage: 45 to 85%RH |
Input terminal connection |
Min. 1×0.5mm2 (1×AWG 20) Max. 1×1.5mm2 (1×AWG 16) or 2×1.5mm2 (2×AWG 16) |
Output terminal connection |
Min. 1×1.5mm2 (1×AWG 16) Max. 1×16mm2 (1×AWG 6) or 2×6mm2 (2×AWG 10) |
Input terminal fixed torque |
0.75 to 0.95N·m |
Output terminal fixed torque |
1.6 to 2.2N.m |
Approval |
CE, cRUus |
Weight |
–Detachable heatsink type : approx. 275g –Integrated heat sink type ( Rated load current 15A/30A/40A: approx. 686g) (Rated load current 50A: approx. 1268g) (Rated load current 75A: approx. 2064g) |
|