Panasonic / Sunx LP-Z Specifications
Excel Automation is an authorized Panasonic / Sunx distributor. Contact us with sales and application support.
Standard(Japanese) model | LP-Z130 | LP-Z250 | LP-Z256 | |
---|---|---|---|---|
FDA compliant model | LP-Z130-A | LP-Z250-A | LP-Z256-A | |
CE marked model | LP-Z130-C | LP-Z250-C | LP-Z256-C | |
Work distance (variable length) |
190 mm (±25 mm) 7.5 in (±0.98 in) |
330 mm (±25 mm) 13.0 in (±0.98 in) |
||
Marking laser | Yb : Fiber laser λ=1060 nm 0.042 mil Class 4 laser product | |||
Pulse width | 30 ns, 100 ns, 200 ns | 50 ns, 100 ns, 200 ns | ||
Average output (Note 1) |
13 W (pulse oscillation) |
25 W (pulse oscillation) |
||
Guide laser/pointer | Semiconductor laser λ=655 nm 0.026 mil Class 2 laser product | |||
Marking field | 120 x 120 mm 4.7 x 4.7 in |
330 x 330 mm 13.0 x 13.0 in |
||
Scanning method | Galvano scanning method | |||
Scan speed | Max. 12,000 mm/s 472 in/s | Max. 8,000 mm/s 315 in/s | ||
Character height / width | 0.1 to 120 mm 0.004 to 4.7 in (Note 2) | 0.1 to 330 mm 0.004 to 13.0 in (Note 2) | ||
Marking spacing (character spacing, line pitch) |
0 to 120 mm 0 to 4.7 in (Note 2) Arced output: –180° to +180° (Note 3) |
0.1 to 330 mm 0.004 to 13.0 in (Note 2) Arced output: –180° to +180° (Note 3) |
||
Marking shape | Straight Line, Arc, Propotional, Justify | |||
Logo data | VEC (Note 4), BMP, DXF, HPGL, JPEG, AI, EPS | |||
Character types | English uppercase letters, English lowercase letters, numerals, katakana, hiragana, kanji (JIS No. 1 and No. 2 standards), symbols, user-registered characters (up to 50) | |||
Barcodes | Code 39, Code 128, ITF, NW-7, JAN (EAN) / UPC, RSS-14 (GS1 DataBar), RSS (GS1 DataBar) Limited, RSS (GS1 DataBar) Expanded | |||
2D codes | QR Code, Micro QR Code, Data Matrix, GS1 Data Matrix | |||
Composite codes | RSS-14 (GS1 DataBar) CC-A, RSS-14 (GS1 DataBar) Stacked CC-A, RSS (GS1 DataBar) Limited CC-A, etc. | |||
Input / Output | Input Terminal, Output Terminal, I/O Connector | |||
Interface | RS-232C, Ethernet(Note 5) | |||
Cooling method | Forced air cooling (Controller / Head) | |||
Power supply | 90 to 132 V AC, 180 to 264 V AC (automatic switching), 50/60 Hz |
|||
Power consumption | 390 VA or less (100 V AC); 420 V or less (200 V AC) | |||
Emergency stop switch | Located on controller | |||
Ambient temperature (Note 6) | 0 to +40 ℃ 32 to 104 ℉ (Controller / Head) |
0 to +35 ℃ 32 to 95 ℉ (Controller / Head) |
||
Ambient temperature for storage (Note 6) | -10 to +60 ℃ 14 to 140 ℉ (Controller / Head) | |||
Ambient humidity (Note 6) | 35 % to 85 % RH (controller / Head) | |||
Net weight | Head : 9.5 kg / Controller : 24 kg |