Tempco Electrical Terminations

/Tempco/Data-Assets/01-Band-Images/WebB114BC.jpg

Type T2: Screw Terminals, One-Piece Band

Standard Termination Location: opposite the gap; center of the width

Minimum Inside Diameter: 2-1/2″ (63.5 mm)

Minimum Width: 1-1/2″ (38.1 mm)

Post Terminals: 10-32 or 8-32

Maximum Volts: 480VAC

Maximum Amps: 25A (10-32) or 20A (8-32)

/Tempco/Data-Assets/01-Band-Images/WebB115BC.jpg

Type T2: Screw Terminals, Two-Piece Band

Standard Termination Location: center each half; center of width

Minimum Inside Diameter: 3″ (76.2 mm)

Minimum Width: 1-1/2″ (38.1 mm)

Post Terminals: 10-32 or 8-32

Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

/Tempco/Data-Assets/01-Band-Images/WebB117BC.jpg

Type T2: Screw Terminals, One-Piece Expandable Band

Standard Termination Location: center each half; center of width

Minimum Inside Diameter: 2-1/2″ (63.5 mm)

Minimum Width: 1-1/2″ (38.1 mm)

Post Terminals: 10-32 or 8-32

Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

/Tempco/Data-Assets/01-Band-Images/WebB118BC.jpg

Type T3X: Screw Terminals, One-Piece Band

Standard Termination Location: opposite the gap; across the center of the width

Minimum Inside Diameter: 2-1/2″ (63.5 mm)

Minimum Width:
with 10-32 Post Terminals — 2-1/2″ (63.5 mm)
with 8-32 Post Terminals — 2″ (50.8 mm)

Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

/Tempco/Data-Assets/01-Band-Images/WebB119BC.jpg

Type T3X: Screw Terminals, Two-Piece Band

Standard Termination Location: opposite the gap; across center of width

Minimum Inside Diameter: 3″ (76.2 mm)

Minimum Width:
with 10-32 Post Terminals — 2-1/2″ (63.5 mm)
with 8-32 Post Terminals — 2″ (50.8 mm)

Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

/Tempco/Data-Assets/01-Band-Images/WebB121BC.jpg

Type T3X: Screw Terminals, One-Piece Expandable Band

Standard Termination Location: opposite the gap; across the center of the width

Minimum Inside Diameter: 2-1/2″ (63.5 mm)

Minimum Width:
with 10-32 Post Terminals — 2-1/2″ (63.5 mm)
with 8-32 Post Terminals — 2″ (50.8 mm)

Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

/Tempco/Data-Assets/01-Band-Images/WebB122BC.jpg

Type T3Y: Screw Terminals, Two-Piece Band

Standard Termination Location: next to the same gap on each half; across the center of the width

Minimum Inside Diameter: 3″ (76.2 mm)

Minimum Width:
with 8-32 Post Terminals — 2″ (50.8 mm)
with 10-32 Post Terminals — 2-1/2″ (63.5 mm)

Maximum Volts: 480VAC each half

Maximum Amps: 25A (10-32) or 20A (8-32) each half

/Tempco/Data-Assets/01-Band-Images/WebB133BC.jpg

Type W1: Abrasion-Resistant Straight Wire Braid Leads, One-Piece Band

Standard Termination Location: opposite the gap; center of the width

Minimum Inside Diameter: 1″ (25.4 mm)

Minimum Width: 1″ (25.4 mm)

Maximum Volts: 480VAC

Maximum Amps: 10

/Tempco/Data-Assets/01-Band-Images/WebB134BC.jpg

Type W1: Abrasion-Resistant Straight Wire Braid Leads, Two-Piece Band

Standard Termination Location: center of each half; center of the width

Minimum Inside Diameter: 3″ (76.2 mm)

Minimum Width: 1″ (25.4 mm)

Maximum Volts: 480VAC each half

Maximum Amps: 10 each half

/Tempco/Data-Assets/01-Band-Images/WebB135BC.jpg

Type W1: Abrasion-Resistant Straight Wire Braid Leads, One-Piece Expandable Band

Standard Termination Location: two sets of leads opposite the gap; center of the width

Minimum Inside Diameter: 2-1/2″ (63.5 mm)

Minimum Width: 1-1/2″ (38.1 mm)

Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebB123BC.jpg

Type W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, One-Piece Band

Standard Termination Location: opposite the gap; the near edge of the width

Minimum Inside Diameter: 1″ (25.4 mm)

Minimum Width: 1″ (25.4 mm)

Maximum Volts: 480VAC

Maximum Amps: 10

/Tempco/Data-Assets/01-Band-Images/WebB125BC.jpg

Type W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, Two-Piece Band

Standard Termination Location: center of each half; near the edge of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebB124BC.jpg

Type W5: Right-Angle Wire Braid Leads, 90 Degrees to Heater Width, One-Piece Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 1″ (25.4 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts: 480VAC
Maximum Amps: 10

/Tempco/Data-Assets/01-Band-Images/WebB126BC.jpg

Type W5: Right-Angle Wire Braid Leads, 90 Degrees to Heater Width, Two-Piece Band

Standard Termination Location: center of each half; center of width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts: 480VAC each half
Maximum Amps: 10 each half

/Tempco/Data-Assets/01-Band-Images/WebB130BC.jpg

Type R1: Abrasion-Resistant Straight Armor Cable, One-Piece Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 1″ (25.4 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts: 480VAC
Maximum Amps: 10

/Tempco/Data-Assets/01-Band-Images/WebB131BC.jpg

Type R1: Abrasion-Resistant Straight Armor Cable, Two-Piece Band

Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebB132BC.jpg

Type R1: Abrasion-Resistant Straight Armor Cable, One-Piece Expandable Band

Standard Termination Location: two sets of leads opposite the gap; center of the width
Minimum Inside Diameter: 2-1/2″ (63.5 mm)
Minimum Width: 1-1/2″ (38.1 mm)
Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebB254BC.jpg

Type R2B: Abrasion-Resistant Right Angle Armor Cable, One-Piece Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 1″ (25.4 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A

/Tempco/Data-Assets/01-Band-Images/WebB255BC.jpg

Type R2B: Abrasion-Resistant Right Angle Armor Cable, Two-Piece Band

Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebB256BC.jpg

Type R2B: Abrasion-Resistant Right Angle Armor Cable, One-Piece Expandable Band

Standard Termination Location: two sets of leads opposite the gap; center of the width
Minimum Inside Diameter: 2-1/2″ (63.5 mm)
Minimum Width: 1-1/2″ (38.1 mm)
Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebBC501.jpg

Type R2H: Abrasion-Resistant Right Angle Armor Cable for Type HTL Lead Wire, One-Piece Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 1-1/2″ (38.1 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A

/Tempco/Data-Assets/01-Band-Images/WebR2H_2pcDrwng.jpg

Type R2H: Abrasion-Resistant Right Angle Armor Cable for Type HTL Lead Wire, Two-Piece Band

Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebR2H_1PcExpndDrwng.jpg

Type R2H: Abrasion-Resistant Right Angle Armor Cable for Type HTL Lead Wire, One-Piece Expandable Band

Standard Termination Location: two sets of leads opposite the gap; center of the width
Minimum Inside Diameter: 2-1/2″ (63.5 mm)
Minimum Width: 1-1/2″ (38.1 mm)
Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebB136BC.jpg

Type C: General Purpose Terminal Box, One-Piece Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts/Amps: 480VAC/25A

/Tempco/Data-Assets/01-Band-Images/WebB137BC.jpg

Type C: General Purpose Terminal Box, Two-Piece Band

Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts/Amps: 480VAC/25A each half

/Tempco/Data-Assets/01-Band-Images/WebB138BC.jpg

Type C: General Purpose Terminal Box, One-Piece Expandable Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts/Amps: 480VAC/25A each half

/Tempco/Data-Assets/01-Band-Images/WebB127BC.jpg

Type L1: Plain Wire Leads, One-Piece Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 1″ (25.4 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A

/Tempco/Data-Assets/01-Band-Images/WebB128BC.jpg

Type L1: Plain Wire Leads, Two-Piece Band

Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 1″ (25.4 mm)
Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebB129BC.jpg

Type L1: Plain Wire Leads, One-Piece Expandable Band

Standard Termination Location: two sets of leads opposite the gap; center of the width
Minimum Inside Diameter: 2-1/2″ (63.5 mm)
Minimum Width: 1-1/2″ (38.1 mm)
Maximum Volts/Amps: 480VAC/10A each half

/Tempco/Data-Assets/01-Band-Images/WebB261BC.jpg

Type P1: High-Temperature Quick Disconnect Plugs, One-Piece Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts: 250VAC     Maximum Amps: 16
Maximum Temperature: 572°F (300°C)

/Tempco/Data-Assets/01-Band-Images/WebB263BC.jpg

Type P1: High-Temperature Quick Disconnect Plugs, Two-Piece Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts: 250VAC    Maximum Amps: 16
Maximum Temperature: 572°F (300°C)

/Tempco/Data-Assets/01-Band-Images/WebB266BC.jpg

Type P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, One-Piece Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts: 250VAC    Maximum Amps: 16
Maximum Temperature: 572°F (300°C)

/Tempco/Data-Assets/01-Band-Images/WebB268BC.jpg

Type P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, Two-Piece Band

Standard Termination Location: center of each half; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts: 250VAC each half    Maximum Amps: 16 each half
Maximum Temperature: 572°F (300°C)

/Tempco/Data-Assets/01-Band-Images/WebB270BC.jpg

Type P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, One-Piece Expandable Band

Standard Termination Location: opposite the gap; center of the width
Minimum Inside Diameter: 3″ (76.2 mm)
Minimum Width: 2″ (50.8 mm)
Maximum Volts: 250VAC each half    Maximum Amps: 16 each half
Maximum Temperature: 572°F (300°C)