Panasonic / Sunx Fan Type lonizer ER-F Specifications
Excel Automation is an authorized Panasonic / Sunx distributor. Contact us with sales and application support.
Type | Standard fan type | Low-volume fan type | |
---|---|---|---|
Model No. | ER-F12A | ER-F12SA | |
CE marking compliant directives | EMC Directive, RoHS Directive | ||
Charge removal time (±1,000 V → ±100 V) |
1 sec. approx. (Note 2) | 1.5 sec. approx. (Note 2) | |
Ion balance | ±10 V or less (Note 3) | ||
Power supply voltage | 24 V DC ±10% | ||
Power consumption | 700 mA or less | 400 mA or less | |
Discharge method | High-frequency AC method | ||
Discharge output voltage | ± 2 kV approx. | ||
Main functions | Error output, Discharge halt input | ||
Indicators | Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green) | ||
Ozone generation amount | 0.04 ppm or less (Note 2) | ||
Ambient temperature | 0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed), Storage: –10℃ to +65℃ +14℉ to +149℉ |
||
Ambient humidity | 35% RH to 65% RH (No dew condensation allowed), Storage: 35% RH to 65% RH |
||
Grounding method | C (capacitor) grounding | ||
Material | Enclosure: ABS, Louver: ABS, Discharge needle unit: PBT, Discharge needle: Tungsten, Bracket: SPHC | ||
Weight | New weight : 790 g approx. | ||
Accessories | Straight louver: 1 pc. (Note 4), Angle louver: 1 pc., Caution label: 1 set, Rubber cushion: 1 pc. |
Discontinued Products
Type | Standard fan type | Low-volume fan type | |
---|---|---|---|
Model No. | ER-F12 | ER-F12S | |
Charge removal time (±1,000 V → ±100 V) |
1 sec. approx. (Note 2) | 1.5 sec. approx. (Note 2) | |
Ion balance | ±10 V or less (Note 3) | ||
Power supply voltage | 24 V DC ±10% | ||
Power consumption | 700 mA or less | 400 mA or less | |
Discharge method | High-frequency AC method | ||
Discharge output voltage | ±2 kV approx. | ||
Max. fan speed | 5.3 m/s (Note 3) | 4.0 m/s (Note 3) | |
Max. fan volume | 3.68 m3/min. | 2.50 m3/min. | |
Error output | NPN open-collector transistor • Max sink current: 50 mA • Applied voltage: 30 V DC or less (between output terminal and 0 V) • Residual voltage: 1 V or less (at input current of 50 mA) |
||
Output operation | OFF when discharge error or fan error detected Normally ON |
||
Short-circuit protection | Incorporated | ||
Discharge halt input | Discharge halt: Short-circuited to 0 V Discharge (operation start): Open |
||
Indicators | Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green) | ||
Ozone generation amount | 0.04 ppm or less (Note 2) | ||
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: –10 to +65 ℃ +14 to +149 ℉ | ||
Ambient humidity | 35 to 65% RH (No dew condensation), Storage: 35 to 65% RH | ||
Grounding method | C (capacitor) grounding | ||
Material | Enclosure: ABS, Louver: ABS, Discharge needle unit: PBT, Discharge needle: Tungsten, Bracket: SPHC | ||
Weight | 4 Main unit: 790 g approx. | ||
Accessories | Straight louver: 1 pc. (Note 4), Angle louver: 1 pc., Caution label: 1 set, Rubber cushion: 1 pc. |